basic accuracy: ± (1.2% of rdg + 3 digits), ± (0.5% of rdg + 5 digits) for 200mV range
input impedance: 7.8Mohm
maximum input: 40-400Hz
AC voltage: 200mV / 2V / 20V / 200V / 600V
basic accuracy: ± (1.5% of rdg + 3 digits), ± (1.5% of rdg + 30 digits) for 200mV range
input impedance: 7.8Mohm
frequency range: 40-400Hz
maximum input: 600V
DC current: -
basic accuracy: -
overload protection: -
AC current: 2/20/200A/400A
basic accuracy: 2A range ± (2.5% of rdg + 6 digits), 20A ~ 200A range ± (2.5% of rdg + 4 digits), 400A range ± (3.0% of rdg + 4 digits)
overload protection:
resistance: 200 / 2K / 20K / 200K / 2M / 20M
basic accuracy: 2A range ± (2.0% of rdg + 4 digits), 2K ~ 200K range ± (1.5% of rdg + 2 digits), 2M range ± (2.0% of rdg + 3 digits), 20M range ± (3.0% of rdg + 5 digits)
overload protection: 250V during max. 15s on all ranges
capacitance: -
accuracy: -
inductance: -
accuracy: -
frequency: -
basic accuracy: -
overload protection: -
temperature: -
basic accuracy: -
overrange: yes "OL"
continuity buzzer: yes
transistor test: no
diode test: yes
low-battery indication: yes
maximum display: 1999
LCD display size: 20 x 30mm
ranging mode: auto / manual
data hold: yes
backlight: yes
dimensions: 205 x 70 x 37mm
weight (with battery): 210g
power supply: 2 x 1.5V AAA batteries (incl.)
packing: box
accessories: manual / test leads / batteries / carrying bag
auto power-off: yes
Bar code
Bar code (EAN-13):5410329399214
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.