Discontinued
-
-
Product description
- CAT III - 600V
- auto range or manual range
- relative measuring possible
- low-battery indication
- diode and continuity test
- voltage measurements: AC 700V and DC 700V max.
- current measurements: max. 10A
- resistance measurements: 40M ohms max.
- sound level measurements: 35-100dB
- resolution: 0.1dB
- typ. instrument frequency: 100Hz to 10kHz
- light measurements: up to 40 000 lux
- accuracy: 5% of rdg + 10 digits
- humidity measurements: 30%~90% RH
- resolution: 0.1% RH
- accuracy: ±5% RH
- temperature measurements: -20°C to +1000°C
- resolution: 0.1°C (-20°C to 400°C) / 1°C (400°C to 1000°C)
- capacitance measurement: 4nF to 200µF
- frequency measurement: 9.999Hz ~ 199.99kHz
- duty cycle measurement: 0.1 ~ 99.9%
- Important safety information
Specifications
- DC voltage: 400mV/4v/40V/400v/600V
- basic accuracy: ±0.7% of rdg + 2 digits (±1.0% of rdg + 2 digits for 600V range)
- input impedance: 10Mohm
- maximum input: 600V
- AC voltage: 4V/40V/400V/600V
- basic accuracy: ±0.8% of rdg + 3 digits (±1.5% of rdg + 5 digits for 600V range)
- input impedance: 10Mohm
- frequency range: 40-400Hz
- maximum input: 600Vac
- DC current: 40mA / 400mA / 10A
- basic accuracy: 40mA & 400mA ±(1.2% of rdg + 3 digits) ; 10A ±(2.0% of rdg + 10 digits)
- overload protection: 0.5A / 250V fast fuse (10A range unfused)
- AC current: 40mA / 400mA / 10A
- basic accuracy: 40mA & 400mA ±(1.5% of rdg + 5 digits) ; 10A ±(3.0% of rdg + 10 digits)
- overload protection: 0.5A / 250V fast fuse (10A range unfused)
- resistance: 400/4K/40K/400K/4M/40M
- basic accuracy: ±1.2% of rdg + 2 digits (±2.0% of rdg + 5 digits for 40M range)
- overload protection: 15 seconds max. 250V on all ranges
- capacitance: 4nF / 40nF / 400nF / 40uF / 200uF
- basic accuracy: 4nF to 40uF ±(3.0% of rdg + 3 digits) ; 200uF ±(8.0% of rdg + 10 digits)
- inductance: -
- frequency: 9.999Hz / 99.99Hz / 999.9Hz / 9.999KHz / 199.9KHz / >200KHz
- basis accuracy: 9.999Hz to 199.99 ±(2.0% of rdg + 5 digits) ; >200KHz for reference only
- overload protection: 250VDC or rms AC
- temperature: -20°c ~ 1000°C
- overrange: yes "OL"
- continuity buzzer: yes
- transistor test: no
- diode test: yes 1.0mA (open circuit voltage = 1.5Vdc)
- low-battery indication: yes
- maximum display: 3999
- LCD display size: -
- ranging mode: manual or automatic
- data hold: yes
- backlight: yes
- dimensions: 85 x 180 x 45mm
- weight (with battery): ± 280g (incl. holster)
- power supply: 9V battery (incl.)
- packing: box
- accessories: manual / test leads / battery
- auto power-off: yes
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.
REACH communicating information according to article 33
|
WEEE