output current selectable by DIP switches 180-295 VAC input only built-in active PFC function protection against: short circuit / overvoltage / over-temperature cooling: free air convection fully isolated plastic case Class II power unit, no FG (frame ground) built-in 0-10 VDC and PWM signal dimming function built-in 12 V / 50 mA auxiliary output IP20 logarithmic or linear dimming curve selectable (meets IEC62386-207) temperature compensation by external NTC thermistor (not incl.) no-load power consumption: < 1 W power supply synchronization function up to 10 units suitable for indoor LED lighting applications 3 years warranty Specifications Physical properties Primary colours Grey Additional colours Blue Depth unit 12.35 cm Height unit 2.3 cm Width unit 8.15 cm Weight unit 240 g Material Plastic + PS/LED
Electrical Properties Power rating 42 W Standby power consumption 1 W Power factor correction function (PFC) Selectable current
Performance & Technical Specs Functionality specifications auxiliary power: 12 V @ 50 mA for driving fan; tolerance ± 5 % temperature compensation: by external NTC thermistor (not provided with the power supply) dimming synchronization Input specifications voltage range: 180-295 VAC 254-417 VDC frequency range: 47-63 Hz power factor (typ.): >= 0.975 / 230 VAC; >= 0.96 / 277 VAC at rated power total harmonic distortion: lower than 20 % when output load is 75 % or higher efficiency (typ.): 91 % AC current (typ.): 0.23 A / 230 VAC; 0.2 A / 277 VAC inrush current (typ.): cold start 20 A (twidth = 260 µs measured at 50 % Ipeak) at 230 VAC leakage current: < 0.5 mA / 240 VAC Output specifications selectable current: 350 mA / 500 mA / 600 mA / 700 mA / 900 mA / 1050 mA DC voltage range: 2-100 V / 2-80 V / 2-67 V / 2-57 V / 2-45 V / 2-40 V rated power: 42 W ripple current: ± 5.0 % ripple & noise (max.): 700 mVp-p no-load output voltage (max.): 110 V / 65 V current accuracy: ± 5.0 % setup, rise time: 500 ms, 80 ms / 230 VAC at rated power hold up time (typ.): 16 ms / 230 VAC at rated power Protection specifications short circuit: constant current limiting, recovers automatically after fault condition is removed overvoltage: 110-130 V protection type: shut down output voltage, re-power on to recover over-temperature: shut down output voltage, re-power on to recover Safety and EMC specifications safety standards: UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent approved withstand voltage: input to output: 3.75 kVAC isolation resistance: input to output: > 100 Mohm / 500 VDC / 25 °C / 70 % RH EMC emission: compliance to EN55015, EN61000-3-2 Class C (>= 40 % rated power); EN61000-3-3 EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2 kV), criteria A Usage location Indoor only Dimmable Dimming type PWM
Installation & Mounting Instruction manual languages English
Maintenance & Lifecycle Mean time between failures (MTBF) MTBF: min. 260,600 h; MIL-HDBK-217F (25 °C)
Environmental & Sustainability Environment specifications operating temperature: -30 to +60 °C operating humidity: 20-90 % RH non-condensing storage: -40 to +80 °C, 10-95 % RH temperature coefficient: ± 0.03 %/°C (0-50 °C) vibration: 10-500 Hz, 2G 10 min/1cycle, period for 60 min each along X, Y, Z axes
output current selectable by DIP switches 180-295 VAC input only built-in active PFC function protection against: short circuit / overvoltage / over-temperature cooling: free air convection fully isolated plastic case Class II power unit, no FG (frame ground) built-in 0-10 VDC and PWM signal dimming function built-in 12 V / 50 mA auxiliary output IP20 logarithmic or linear dimming curve selectable (meets IEC62386-207) temperature compensation by external NTC thermistor (not incl.) no-load power consumption: < 1 W power supply synchronization function up to 10 units suitable for indoor LED lighting applications 3 years warranty Specifications Physical properties Primary colours Grey Additional colours Blue Depth unit 12.35 cm Height unit 2.3 cm Width unit 8.15 cm Weight unit 240 g Material Plastic + PS/LED
Electrical Properties Power rating 42 W Standby power consumption 1 W Power factor correction function (PFC) Selectable current
Performance & Technical Specs Functionality specifications auxiliary power: 12 V @ 50 mA for driving fan; tolerance ± 5 % temperature compensation: by external NTC thermistor (not provided with the power supply) dimming synchronization Input specifications voltage range: 180-295 VAC 254-417 VDC frequency range: 47-63 Hz power factor (typ.): >= 0.975 / 230 VAC; >= 0.96 / 277 VAC at rated power total harmonic distortion: lower than 20 % when output load is 75 % or higher efficiency (typ.): 91 % AC current (typ.): 0.23 A / 230 VAC; 0.2 A / 277 VAC inrush current (typ.): cold start 20 A (twidth = 260 µs measured at 50 % Ipeak) at 230 VAC leakage current: < 0.5 mA / 240 VAC Output specifications selectable current: 350 mA / 500 mA / 600 mA / 700 mA / 900 mA / 1050 mA DC voltage range: 2-100 V / 2-80 V / 2-67 V / 2-57 V / 2-45 V / 2-40 V rated power: 42 W ripple current: ± 5.0 % ripple & noise (max.): 700 mVp-p no-load output voltage (max.): 110 V / 65 V current accuracy: ± 5.0 % setup, rise time: 500 ms, 80 ms / 230 VAC at rated power hold up time (typ.): 16 ms / 230 VAC at rated power Protection specifications short circuit: constant current limiting, recovers automatically after fault condition is removed overvoltage: 110-130 V protection type: shut down output voltage, re-power on to recover over-temperature: shut down output voltage, re-power on to recover Safety and EMC specifications safety standards: UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent approved withstand voltage: input to output: 3.75 kVAC isolation resistance: input to output: > 100 Mohm / 500 VDC / 25 °C / 70 % RH EMC emission: compliance to EN55015, EN61000-3-2 Class C (>= 40 % rated power); EN61000-3-3 EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2 kV), criteria A Usage location Indoor only Dimmable Dimming type PWM
Installation & Mounting Instruction manual languages English
Maintenance & Lifecycle Mean time between failures (MTBF) MTBF: min. 260,600 h; MIL-HDBK-217F (25 °C)
Environmental & Sustainability Environment specifications operating temperature: -30 to +60 °C operating humidity: 20-90 % RH non-condensing storage: -40 to +80 °C, 10-95 % RH temperature coefficient: ± 0.03 %/°C (0-50 °C) vibration: 10-500 Hz, 2G 10 min/1cycle, period for 60 min each along X, Y, Z axes
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.
REACH communicating information according to article 33 |WEEE