Product description
Current measurement combined with accurate multimeter functions eliminate the need to carry both a current clamp and a multimeter.
This current clamp is suitable for AC/DC current measurements up to 600 A and AC/DC voltage measurements up to 600 V. The measuring range can be set automatically or manually. Besides voltage and current, the meter is also suitable for measuring temperature, resistance, continuity and diodes.
The meter has a 3999 count display with backlight, making measurements easy to read, and a torch for dark rooms. The data hold function allows the instrument to be used on hard-to-reach cables where the display would otherwise be impossible to read. The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables.
The measuring device is particularly robust and offers high safety according to measurement category CAT III 600 V. |
+ Safety: The current clamp measures the current without touching the current-carrying conductor (e.g. wire).+ Easy measurement: During a measurement, there is no need to interrupt the circuit.+ Non-contact voltage detection: The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables.+ Versatile: The current clamp measures alternating current, voltage, temperature, resistance, diodes and continuity.+ Automatic and manual range setting. Specifications| Physical properties |
|---|
| Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) | | Primary colours | Red | | Display height | 24 mm | | Additional colours | Yellow | | Depth unit | 35 mm | | Height unit | 194 mm | | Width unit | 72 mm | | Weight unit | 230 g | | Display width | 37 mm |
| Electrical Properties |
|---|
| Battery voltage rating | 4.5 V | | Maximum DC current | 600 A | | Automatic power-off function | | | AC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A - 600 A range
| | AC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 0.4 V range
- ± (1.0 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.2 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- frequency range: 50 - 1000 Hz
- maximum input: 600 V
| | DC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A ~ 600 A range
| | DC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (0.5 % of rdg + 3 digits) for 0.4 V range
- ± (0.8 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.0 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- maximum input: 600 V
| | Frequency | - 10 Hz/100 Hz/1 KHz/10 KHz/100 KHz/1 MHz/10 MHz
- basic accuracy:
- ± (0.5 % of rdg + 2 digits) for 10 Hz - 10 MHz range
- overload protection: 15 s max. 250 V (all ranges)
| | AC current measurements | 40 A,400 A,600 A | | AC voltage measurements | 4 V,40 V,400 V,600 V,400 mV | | DC current measurements | 40 A,400 A,600 A | | DC voltage measurements | 400 mV,4 V,40 V,400 V,600 V | | Frequency measurements | 10 Hz,100 Hz,1000 Hz,10 kHz,100 kHz,1 MHz,10 MHz | | Maximum AC current | 600 A | | Minimum input voltage rating VAC | 0 V | | Maximum input voltage rating VAC | 600 V | | Input voltage rating VDC 1 | 0 V | | Input voltage rating VDC 2 | 600 V |
| Lighting & Optical Properties |
|---|
| LED light | |
| Chemical & Material Composition |
|---|
| Battery composition | Alkaline |
| Functional Features |
|---|
| Data-hold function | |
| Performance & Technical Specs |
|---|
| Capacity measurements | 10 nF,100 nF,1 µF,10 µF,100 µF,1 mF,10 mF,100 mF | | Diode test | | | Duty cycle | - 0.5 - 99 % @ pulse width of 100 µs to 100 ms
| | Maximum duty cycle measurements | 99 % | | Minimum duty cycle measurements | 0.5 % | | Pollution degree | 2 | | Resistance measurements | 400 Ohm,4 kOhm,40 kOhm,400 kOhm,4 MOhm,40 MOhm | | Resistance specifications | - 400/4 K/40 K/400 K/4 M/ 40 Mohm
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 400 ohm range
- ± (0.8 % of rdg + 5 digits) for 4 K - 4 Mohm range
- ± (2.0 % of rdg + 10 digits) for 40 Mohm range
- overload protection: 15 s max. 250 V (all ranges)
| | Temperature specifications | - -20 °C - 1000 °C
- basic accuracy:
- ± (5 % of rdg + 4 °C) for -20 °C to 0 °C range
- ± (2 % of rdg + 3 °C) for 0 °C to 400 °C range
- ± (3 % of rdg + 3 °C) for 400 °C to 1000 °C range
- overload protection: 15 s max. 250 V
| | True rms | | | Battery required | | | Number of batteries | 3 | | Battery operated | | | Overload protection | | | Low battery indicator | | | Alarm type | Buzzer | | Continuity test | | | Backlight | | | Maximum digits display | 3999 |
| Installation & Mounting |
|---|
| Instruction manual languages | Dutch,English,French,German,Polish,Portuguese,Spanish |
| Compliance & Certification |
|---|
| Safety rating | Cat III / 600 V | | Safety standard | EN 61010-1 |
|
+ Safety: The current clamp measures the current without touching the current-carrying conductor (e.g. wire).+ Easy measurement: During a measurement, there is no need to interrupt the circuit.+ Non-contact voltage detection: The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables.+ Versatile: The current clamp measures alternating current, voltage, temperature, resistance, diodes and continuity.+ Automatic and manual range setting. | |
Specifications| Physical properties |
|---|
| Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) | | Primary colours | Red | | Display height | 24 mm | | Additional colours | Yellow | | Depth unit | 35 mm | | Height unit | 194 mm | | Width unit | 72 mm | | Weight unit | 230 g | | Display width | 37 mm |
| Electrical Properties |
|---|
| Battery voltage rating | 4.5 V | | Maximum DC current | 600 A | | Automatic power-off function | | | AC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A - 600 A range
| | AC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 0.4 V range
- ± (1.0 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.2 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- frequency range: 50 - 1000 Hz
- maximum input: 600 V
| | DC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A ~ 600 A range
| | DC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (0.5 % of rdg + 3 digits) for 0.4 V range
- ± (0.8 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.0 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- maximum input: 600 V
| | Frequency | - 10 Hz/100 Hz/1 KHz/10 KHz/100 KHz/1 MHz/10 MHz
- basic accuracy:
- ± (0.5 % of rdg + 2 digits) for 10 Hz - 10 MHz range
- overload protection: 15 s max. 250 V (all ranges)
| | AC current measurements | 40 A,400 A,600 A | | AC voltage measurements | 4 V,40 V,400 V,600 V,400 mV | | DC current measurements | 40 A,400 A,600 A | | DC voltage measurements | 400 mV,4 V,40 V,400 V,600 V | | Frequency measurements | 10 Hz,100 Hz,1000 Hz,10 kHz,100 kHz,1 MHz,10 MHz | | Maximum AC current | 600 A | | Minimum input voltage rating VAC | 0 V | | Maximum input voltage rating VAC | 600 V | | Input voltage rating VDC 1 | 0 V | | Input voltage rating VDC 2 | 600 V |
| Lighting & Optical Properties |
|---|
| LED light | |
| Chemical & Material Composition |
|---|
| Battery composition | Alkaline |
| Functional Features |
|---|
| Data-hold function | |
| Performance & Technical Specs |
|---|
| Capacity measurements | 10 nF,100 nF,1 µF,10 µF,100 µF,1 mF,10 mF,100 mF | | Diode test | | | Duty cycle | - 0.5 - 99 % @ pulse width of 100 µs to 100 ms
| | Maximum duty cycle measurements | 99 % | | Minimum duty cycle measurements | 0.5 % | | Pollution degree | 2 | | Resistance measurements | 400 Ohm,4 kOhm,40 kOhm,400 kOhm,4 MOhm,40 MOhm | | Resistance specifications | - 400/4 K/40 K/400 K/4 M/ 40 Mohm
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 400 ohm range
- ± (0.8 % of rdg + 5 digits) for 4 K - 4 Mohm range
- ± (2.0 % of rdg + 10 digits) for 40 Mohm range
- overload protection: 15 s max. 250 V (all ranges)
| | Temperature specifications | - -20 °C - 1000 °C
- basic accuracy:
- ± (5 % of rdg + 4 °C) for -20 °C to 0 °C range
- ± (2 % of rdg + 3 °C) for 0 °C to 400 °C range
- ± (3 % of rdg + 3 °C) for 400 °C to 1000 °C range
- overload protection: 15 s max. 250 V
| | True rms | | | Battery required | | | Number of batteries | 3 | | Battery operated | | | Overload protection | | | Low battery indicator | | | Alarm type | Buzzer | | Continuity test | | | Backlight | | | Maximum digits display | 3999 |
| Installation & Mounting |
|---|
| Instruction manual languages | Dutch,English,French,German,Polish,Portuguese,Spanish |
| Compliance & Certification |
|---|
| Safety rating | Cat III / 600 V | | Safety standard | EN 61010-1 |
| |
|
Customers who viewed this product also viewed
BESTSELLER Digital multimeter, data hold, non-contact voltage... BESTSELLER Digital multimeter, data hold, non-contact voltage... LBL_NONE_TAG Digital multimeter, datahold, suitable for measuring AC/DC... LBL_NONE_TAG Digital multimeter, suitable for measuring AC/DC current,... All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only. REACH communicating information according to article 33 |WEEE |