This compact measurement tool is ideal for testing Zener diodes, avalanche diodes, VDRs, TVS devices and LED strings up to 50 V. It accurately measures breakdown voltage and slope resistance, and continuously displays results at a refresh rate of 3 Hz. The hold function allows values to be retained even after removing the component. |
+ Zener voltage range up to 50 V: This analyzer measures breakdown voltages from 0.00 V to 50.00 V with a precise 20 mV resolution.+ High-resolution slope resistance measurement: Slope resistance is measured up to 1 kOhm at 15 mA, with resolutions down to 1 Ohm depending on the selected test current.+ Multiple selectable test currents: Choose between 2 mA, 5 mA, 10 mA or 15 mA to suit different diode types and TVS components.+ Reduced heating through low duty cycle: The pulsed test current, typically 1%, limits heating even when testing at full voltage and current.+ Continuous readings with hold function: Results are updated three times per second. The hold mode allows captured readings to remain visible after disconnecting the component. Specifications| Physical properties |
|---|
| Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) | | Primary colours | Green | | Depth unit | 70 mm | | Height unit | 103 mm | | Width unit | 70 mm | | Weight unit | 98 g | | Material | ABS | | Additional material | Glass,Metal |
| Electrical Properties |
|---|
| Minimum battery voltage rating | 0.9 V | | Maximum battery voltage rating | 1.6 V |
| Chemical & Material Composition |
|---|
| Battery composition | Alkaline |
| Performance & Technical Specs |
|---|
| Specifications | - specification summary at 20-25 °C (68-77 °F) unless otherwise specified
- Zener voltage range (Vz): 0.0 V - 50.0 V
- nominal test currents (Iz) : 2mA, 5mA, 10mA, 15mA
- set test current accuracy: ± 1 % ± 0.2 mA
- Zener voltage measurement accuracy: ± 1% ± 40 mV
- Zener voltage measurement resolution : 20 mV - 40 mV
- test frequency accuracy: -1.5% ~ +1.5%
- 60 V pulsed DC satisfies lower limit of 75 V(DC) for Low Voltage Directive 2006/95/EC
- test current into a short circuit (pulsed) : 35 mA
- test current duty cycle :
- min: 0.1%
- max: 5%
- typical: 1%
- duty cycle of test current designed to keep power dissipation of Zener under test to very low levels
- maximum external voltage: ± 50 V
| | Specifications extra | - slope resistance measurement range:
- Iz = 2 mA (slope resistance measurement range): 0-8000 Ohm
- Iz = 5 mA (slope resistance measurement range): 0-3200 Ohm
- Iz = 10 mA (slope resistance measurement range): 0-1600 Ohm
- Iz = 15 mA (slope resistance measurement range): 0-1000 Ohm
- displayed slope resistance resolution:
- Iz = 2 mA (displayed slope resistance resolution): 5 Ohm
- Iz = 5 mA (displayed slope resistance resolution): 2 Ohm
- Iz = 10 mA (displayed slope resistance resolution): 1 Ohm
- Iz = 15 mA (displayed slope resistance resolution): 1 Ohm
| | Specifications extra extra | - slope resistance measurement accuracy:
- Iz = 2 mA (slope resistance measurement accuracy): ±1% ±10 Ohm
- Iz = 5 mA (slope resistance measurement accuracy): ±1% ±4 Ohm
- Iz = 10 mA (slope resistance measurement accuracy): ±1% ±2 Ohm
- Iz = 15 mA (slope resistance measurement accuracy): ±1% ±2 Ohm
- slope resistance current span: (Iz-50%) to (Iz+50%)
- slope resistance measurement method :
- differentiation of curve that fits:: (Iz-50%, Vz1), (Iz, Vz2), (Iz+50%, Vz3)
- measurement rate: 3 Hz
- auto-off period: 60 sec.
| | Maximum operating temperature | 40 °C | | Minimum operating temperature | 10 °C | | Detailed information | - test Zener diodes, Avalanche diodes, VDRs, TVSs, LED strings and much more (up to 50 V)
- measures breakdown voltage (0.00 V to 50.00 V) with a resolution as fine as 20 mV
- measures slope resistance (up to 1 kO at 15 mA with a 1O resolution)
- supports most Zeners, Avalanche diodes and reference diodes from 0 V up to 50 V
- great for testing VDRs, TVSs and other types of voltage protection devices
- selectable test currents: 2 mA, 5 mA, 10 mA, 15 mA
- tiny duty cycle of test current to minimise heating of your component, even when testing at 50 V and 15 mA
- continuous measurement display (updated 3 times per second)
- hold-function to hold displayed values even if component is removed
| | Number of batteries | 1 | | Low battery indicator | |
|
+ Zener voltage range up to 50 V: This analyzer measures breakdown voltages from 0.00 V to 50.00 V with a precise 20 mV resolution.+ High-resolution slope resistance measurement: Slope resistance is measured up to 1 kOhm at 15 mA, with resolutions down to 1 Ohm depending on the selected test current.+ Multiple selectable test currents: Choose between 2 mA, 5 mA, 10 mA or 15 mA to suit different diode types and TVS components.+ Reduced heating through low duty cycle: The pulsed test current, typically 1%, limits heating even when testing at full voltage and current.+ Continuous readings with hold function: Results are updated three times per second. The hold mode allows captured readings to remain visible after disconnecting the component. | |
Specifications| Physical properties |
|---|
| Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) | | Primary colours | Green | | Depth unit | 70 mm | | Height unit | 103 mm | | Width unit | 70 mm | | Weight unit | 98 g | | Material | ABS | | Additional material | Glass,Metal |
| Electrical Properties |
|---|
| Minimum battery voltage rating | 0.9 V | | Maximum battery voltage rating | 1.6 V |
| Chemical & Material Composition |
|---|
| Battery composition | Alkaline |
| Performance & Technical Specs |
|---|
| Specifications | - specification summary at 20-25 °C (68-77 °F) unless otherwise specified
- Zener voltage range (Vz): 0.0 V - 50.0 V
- nominal test currents (Iz) : 2mA, 5mA, 10mA, 15mA
- set test current accuracy: ± 1 % ± 0.2 mA
- Zener voltage measurement accuracy: ± 1% ± 40 mV
- Zener voltage measurement resolution : 20 mV - 40 mV
- test frequency accuracy: -1.5% ~ +1.5%
- 60 V pulsed DC satisfies lower limit of 75 V(DC) for Low Voltage Directive 2006/95/EC
- test current into a short circuit (pulsed) : 35 mA
- test current duty cycle :
- min: 0.1%
- max: 5%
- typical: 1%
- duty cycle of test current designed to keep power dissipation of Zener under test to very low levels
- maximum external voltage: ± 50 V
| | Specifications extra | - slope resistance measurement range:
- Iz = 2 mA (slope resistance measurement range): 0-8000 Ohm
- Iz = 5 mA (slope resistance measurement range): 0-3200 Ohm
- Iz = 10 mA (slope resistance measurement range): 0-1600 Ohm
- Iz = 15 mA (slope resistance measurement range): 0-1000 Ohm
- displayed slope resistance resolution:
- Iz = 2 mA (displayed slope resistance resolution): 5 Ohm
- Iz = 5 mA (displayed slope resistance resolution): 2 Ohm
- Iz = 10 mA (displayed slope resistance resolution): 1 Ohm
- Iz = 15 mA (displayed slope resistance resolution): 1 Ohm
| | Specifications extra extra | - slope resistance measurement accuracy:
- Iz = 2 mA (slope resistance measurement accuracy): ±1% ±10 Ohm
- Iz = 5 mA (slope resistance measurement accuracy): ±1% ±4 Ohm
- Iz = 10 mA (slope resistance measurement accuracy): ±1% ±2 Ohm
- Iz = 15 mA (slope resistance measurement accuracy): ±1% ±2 Ohm
- slope resistance current span: (Iz-50%) to (Iz+50%)
- slope resistance measurement method :
- differentiation of curve that fits:: (Iz-50%, Vz1), (Iz, Vz2), (Iz+50%, Vz3)
- measurement rate: 3 Hz
- auto-off period: 60 sec.
| | Maximum operating temperature | 40 °C | | Minimum operating temperature | 10 °C | | Detailed information | - test Zener diodes, Avalanche diodes, VDRs, TVSs, LED strings and much more (up to 50 V)
- measures breakdown voltage (0.00 V to 50.00 V) with a resolution as fine as 20 mV
- measures slope resistance (up to 1 kO at 15 mA with a 1O resolution)
- supports most Zeners, Avalanche diodes and reference diodes from 0 V up to 50 V
- great for testing VDRs, TVSs and other types of voltage protection devices
- selectable test currents: 2 mA, 5 mA, 10 mA, 15 mA
- tiny duty cycle of test current to minimise heating of your component, even when testing at 50 V and 15 mA
- continuous measurement display (updated 3 times per second)
- hold-function to hold displayed values even if component is removed
| | Number of batteries | 1 | | Low battery indicator | |
| |
|