Product description
- ultra slim design with 52.5 mm (3SU) width
- universal input 85-264 VAC (277 VAC operational)
- no load power consumption < 0.3 W
- isolation class II
- pass LPS (limited power source)
- DC output voltage adjustable
- protections: short circuit / overload / over voltage
- cooling by free air convection (working temperature : -30 - +70°C)
- DIN rail TS-35/7.5 or 15 mountable
- over voltage category III
- LED indicator power on
- 3 year warranty
- for professional use only
- This device must be installed by a qualified person.
Specifications- output:
- DC voltage: 5 V
- rated current: 6.5 A
- current range: 0 - 6.5 A
- rated power: 32.5 W
- ripple & noise (max.): 80 mVp-p
- voltage adj. range: 5.0 - 5.5 V
- voltage tolerance: ± 2.0 %
- line regulation: ± 1.0 %
- load regulation: ± 1.0 %
- setup, rise time: 500 ms, 50 ms / 230 VAC - 500 ms, 50 ms / 115 VAC at full load
- hold up time (typ.): 30 ms / 230 VAC - 12 ms / 115 VAC at full load
- input:
- voltage range: 85-264 VAC (277 VAC operational) - 120-370 VDC (390 VDC operational)
- frequency range: 47 - 63 Hz
- efficiency (typ.): 85 %
- ac current (typ.): 1.2 A / 115 VAC - 0.8 A / 230 VAC
- inrush current (typ.): cold start 30 A / 115 VAC - 60 A / 230 VAC
- protection:
- overload:
- 105 - 160 % rated output power
- protection type: constant current limiting, recovers automatically after fault condition is removed
- overvoltage:
- 5.75 - 6.75 V
- protection type: shut down output voltage, re-power on to recover
- environment:
- working temperature: -30 to +70 °C
- working humidity: 20 to 90 % RH non-condensing
- storage: -40 to +85 °C, 10 to 95% RH
- temperature coefficient: ± 0.03 %/°C (0 - 50°C )
- vibration: 10 - 500 Hz, 2G 10 min / 1 cycle, 60 min each along X, Y, Z axes; mounting: compliance to IEC60068-2-6
- operating altitude: 2000 m
- over voltage category: III, according to EN61558, EN50178, EN60664-1, EN62477-1, altitude up to 2000 meters
- safety & EMC:
- safety standards: UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved, design refer to TUV EN60950-1
- withstand voltage: input to output: 4 kVAC
- isolation resistance: input to output: 100 MOhm / 500 VDC / 25 °C / 70 % RH
- EMC emission:
- conducted (EMC emission): EN55032 (CISPR32) / Class B
- radiated: EN55032 (CISPR32) / Class B
- harmonic current: EN61000-3-2 / Class A
- voltage flicker: EN61000-3-3
- EMC immunity:
- ESD: EN61000-4-2 / Level 3, 8KV air - Level 2, 4KV contact - criteria A
- radiated susceptibility: EN61000-4-3 / Level 3 - criteria A
- EFT/Burest: EN61000-4-4 / Level 3 - criteria A
- surge: EN61000-4-5 / Level 4, 2KV/L-N - criteria A
- conducted (EMC immunity): EN61000-4-6 / Level 3 - criteria A
- magnetic field: EN61000-4-8 / Level 4, criteria A
- voltage dips and interruptions: EN61000-4-11 / >95% dip 0.5 periods, 30% dip 25 periods - >95% interruptions 250 periods
- other:
- MTBF: 927.6Kh, MIL-HDBK-217F (25 °C)
- dimensions: 52.5 x 90 x 54.5 mm (W x H x D)
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only. REACH communicating information according to article 33 |WEEE |