Product description
Current measurement combined with accurate multimeter functions eliminate the need to carry both a current clamp and a multimeter. This current clamp is suitable for AC/DC current measurements up to 600 A and AC/DC voltage measurements up to 600 V. The measuring range can be set automatically or manually. Besides voltage and current, the meter is also suitable for measuring temperature, resistance, continuity and diodes. The meter has a 3999 count display with backlight, making measurements easy to read, and a torch for dark rooms. The data hold function allows the instrument to be used on hard-to-reach cables where the display would otherwise be impossible to read. The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables. The measuring device is particularly robust and offers high safety according to measurement category CAT III 600 V. + Safety: The current clamp measures the current without touching the current-carrying conductor (e.g. wire). + Easy measurement: During a measurement, there is no need to interrupt the circuit. + Non-contact voltage detection: The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables. + Versatile: The current clamp measures alternating current, voltage, temperature, resistance, diodes and continuity. + Automatic and manual range setting.
SpecificationsProduct basic info |
---|
Instruction manual languages | Dutch, English, French, German, Polish, Portuguese, Spanish | Primary colours | Red | Additional colours | Yellow | Depth unit | 35 mm | Height unit | 194 mm | Width unit | 72 mm | Weight unit | 230 g |
Physical properties |
---|
Display height | 24 mm | Display width | 37 mm | LED light | | Backlight | | Maximum digits display | 3999 |
Electrical data |
---|
Capacitance specifications | - 10 n/100 n/1 µ/10 µ/100 µ/1 m/10 m/100 mF
- accuracy:
- ± (4.0 % of rdg + 25 digits) for 10 nF range
- ± (4.0 % of rdg + 15 digits) for 100 nF - 100 µF range
- ± (5.0 % of rdg + 25 digits) for 1 mF - 100 mF range
- overload protection: 15 s max. 250 V (all ranges)
| Overload protection | | Maximum DC current | 600 A | AC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A - 600 A range
| AC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 0.4 V range
- ± (1.0 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.2 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- frequency range: 50 - 1000 Hz
- maximum input: 600 V
| DC current | - 40/400/600 A (max. line voltage 240 V)
- basic accuracy:
- ± (2.5 % of rdg + 10 digits) for 40 A ~ 600 A range
| DC voltage | - 0.4/4/40/400/600 V
- basic accuracy:
- ± (0.5 % of rdg + 3 digits) for 0.4 V range
- ± (0.8 % of rdg + 5 digits) for 4 V - 400 V range
- ± (1.0 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- maximum input: 600 V
| Diode test | | Duty cycle | - 0.5 - 99 % @ pulse width of 100 µs to 100 ms
| Continuity test | | Frequency | - 10 Hz/100 Hz/1 KHz/10 KHz/100 KHz/1 MHz/10 MHz
- basic accuracy:
- ± (0.5 % of rdg + 2 digits) for 10 Hz - 10 MHz range
- overload protection: 15 s max. 250 V (all ranges)
| True rms | | AC current measurements | 40 A, 400 A, 600 A | AC voltage measurements | 4 V, 40 V, 400 mV, 400 V, 600 V | Capacity measurements | 1 µF, 1 mF, 10 µF, 10 mF, 10 nF, 100 µF, 100 mF, 100 nF | DC current measurements | 40 A, 400 A, 600 A | DC voltage measurements | 4 V, 40 V, 400 mV, 400 V, 600 V | Frequency measurements | 1 MHz, 10 Hz, 10 kHz, 10 MHz, 100 Hz, 100 kHz, 1000 Hz | Duty cycle measurements | 0.5-99 % | Resistance measurements | 4 kOhm, 4 MOhm, 40 kOhm, 40 MOhm, 400 kOhm, 400 Ohm | Resistance specifications | - 400/4 K/40 K/400 K/4 M/ 40 Mohm
- basic accuracy:
- ± (1.0 % of rdg + 10 digits) for 400 ohm range
- ± (0.8 % of rdg + 5 digits) for 4 K - 4 Mohm range
- ± (2.0 % of rdg + 10 digits) for 40 Mohm range
- overload protection: 15 s max. 250 V (all ranges)
| Maximum AC current | 600 A |
Technical data |
---|
Safety standard | EN 61010-1 | Safety rating | Cat III / 600 V | Automatic power-off function | | Pollution degree | 2 | Data-hold function | |
Set-up options |
---|
Alarm sound type | Buzzer |
Environmental data |
---|
Temperature specifications | - -20 °C - 1000 °C
- basic accuracy:
- ± (5 % of rdg + 4 °C) for -20 °C to 0 °C range
- ± (2 % of rdg + 3 °C) for 0 °C to 400 °C range
- ± (3 % of rdg + 3 °C) for 400 °C to 1000 °C range
- overload protection: 15 s max. 250 V
|
Power supply |
---|
Battery required | | Number of batteries | 3 | Input voltage rating VAC range | 0-600 V | Battery operated | | Battery voltage rating | 4.5 V | Input voltage rating VDC range | 0-600 V | Low battery indicator | | Battery composition | Alkaline | Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) |