Product description
Current measurement combined with accurate multimeter functions eliminate the need to carry both a current clamp and a multimeter. This current clamp is suitable for AC current measurements up to 500 A and AC/DC voltage measurements up to 600 V. The measuring range can be set automatically or manually (0 to 2 A and 20 A to 500 A). Besides voltage and current, the meter is also suitable for measuring resistance, continuity and diodes. The data hold function allows the instrument to be used on hard-to-reach cables where the display would otherwise be impossible to read. The measuring device is particularly robust and offers high safety according to measurement category CAT III 600 V.
+ Safety: The current clamp measures the current without touching the current-carrying conductor (e.g. wire). + Easy measurement: During a measurement, there is no need to interrupt the circuit. + User-friendly: The current clamp is easy to operate and displays measured values on the digital display. + Versatile: The current clamp measures alternating current, voltage, resistance, diodes and continuity. + Automatic and manual range setting (0 to 2 A and 20 A to 500 A).
Specifications
Product basic info |
---|
Instruction manual languages | Dutch, English, French, German, Polish, Portuguese, Spanish | Primary colours | Red | Additional colours | Yellow | Depth unit | 24.8 mm | Height unit | 131.5 mm | Width unit | 61 mm | Weight unit | 135 g | Material | ABS |
Physical properties |
---|
Display height | 18 mm | Display width | 39 mm | LED light | | Backlight | | Maximum digits display | 1999 |
Electrical data |
---|
Overload protection | | AC current | - 2/20/200/500 A
- basic accuracy:
- ± (4.0 % of rdg + 10 digits) for 2 A range
- ± (2.5 % of rdg + 5 digits) for 20 A ~ 500 A range
- 1200 A for max. 60 seconds
| AC voltage | - 2/20/200/600 V
- basic accuracy:
- ± (1.5 % of rdg + 3 digits) for 2 V ~ 200 V range
- ± (1.5 % of rdg + 5 digits) for 600 V range
- input impedance: 10 Mohm
- frequency range: 50-60 Hz
- maximum input: 600 V
| Continuity test | | DC voltage | - 0.2/2/20/200/600 V
- basic accuracy:
- ± (0.8 % of rdg + 3 digits) for 0.2 V range
- ± (1.2 % of rdg + 3 digits) for 2 V ~ 600 V range
- input impedance: 10 Mohm
- maximum input: 600 V
| Diode test | | True rms | | AC current measurements | 2 A, 20 A, 500 A | AC voltage measurements | 2 V, 20 V, 200 V, 600 V | DC voltage measurements | 2 V, 20 V, 200 mV, 200 V, 600 V | Resistance specifications | - 200/2K/20K/200K/2M/20M
- basic accuracy:
- ± (1.0 % of rdg + 2 digits) for 200 ohm range
- ± (1.5 % of rdg + 2 digits) for 2 K ~ 2 M range
- ± (2.0 % of rdg + 3 digits) for 20 M range
- overload protection: 15 s max. 250 V (all ranges)
| Maximum AC current | 500 A |
Technical data |
---|
Safety standard | EN 61010-1 | Safety rating | Cat III / 600 V | Automatic power-off function | | Pollution degree | 2 | Data-hold function | | Colour of LEDs | Red, White |
Set-up options |
---|
Alarm sound type | Buzzer |
Power supply |
---|
Battery required | | Number of batteries | 3 | Input voltage rating VAC range | 0-600 V | Battery operated | | Battery voltage rating | 4.5 V | Input voltage rating VDC range | 0-600 V | Low battery indicator | | Battery composition | Alkaline | Battery IEC size | AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400) |
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.