Product description
- 230 VAC only or full range (up to 295 VAC) models available
- built-in active PFC function
- constant current design
- protections: short circuit
- cooling by free air convection
- fully isolated plastic case
- class II power unit, no FG
- no load power consumption <0.5W
- high reliability, low cost
Specifications
- output:
- rated current: 1400 mA
- operating voltage range: 15 - 29 V
- current accuracy: 8.0 %
- rated power: 40.6 W
- ripple & noise (max): 3 Vp-p
- no load output voltage: 34 V
- setup time: 500 ms / 230 VAC at full load
- input:
- voltage range: 180 - 295 VAC, 254 - 417 VDC
- frequency range: 47 - 63 Hz
- power factor: PF > 0.95 / 230 VAC, PF > 0.9 / 277 VAC (at full load)
- total harmonic: THD < 20% when output loading > 60% at 230 VAC input and output loading > 75% at 277 VAC input
- efficiency: 86 %
- AC current: 0.3 A/ 230 VAC, 0.25 A / 277 VAC
- inrush current: cold start 15 A (twidth=50µs measured at 50% Ipeak) at 230 VAC
- MAX. No. of PSUs on 16A circuit breaker: 47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230 VAC
- leakage current: < 0.5 mA / 240 VAC
- protection:
- short circuit: hiccup mode, recovers automatically after fault condition is removed
- over temperature: hiccup mode, recovers automatically after temperature goes down
- environment:
- working temperature: -30 - +40 °C
- working humidity: 20 - 95% RH non-condensing
- storage temperature, humidity: -40 - +80 °C, 10 - 95% RH
- temperature coefficient: ±0.06% / °C (0 - 40 °C)
- vibration: 10 - 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes
- safety & EMC:
- safety standards: UL8750, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13, EN62384, GB19510.14,GB19510.1),IP30 approved
- withstand voltage: I/P-O/P:3.75K VAC
- isolation resistance: I/P-O/P:100M Ohms / 500 VDC / 25 °C / 70% RH
- EMC emission: compliance to EN55015, GB17743, GB17625.1,EN61000-3-2 Class C(> 75% load);EN61000-3-3
- EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11;EN61547, light industry level, criteria B(surge 2KV)
- others:
- MTBF: 822.7K hrs min. MIL-HDBK-217F (25 °C)
- dimensions: 175 x 42 x 24 mm (L x W x H)
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.
REACH communicating information according to article 33
|
WEEE
|