USA - English (UK)
Change
Based on your location we recommend you to visit www.vellemanusa.com

SWITCHING POWER SUPPLY - SINGLE OUTPUT - 600 W - 24 V

HLG-600H-24A
Support
Downloads (2)
Warranty
Support
Compare

Features

  • universal AC input / full range (up to 305 VAC)
  • built-in active PFC function
  • no load power consumption <0.5W at remote OFF
  • high efficiency up to 96%
  • -40 °C - +70°C wide operating range
  • protections: short-circuit / overload / overvoltage / overtemperature
  • cooling by free air convection
  • IP65 design for indoor or outdoor installations
  • withstand 5G vibration test
  • three in one dimming function
  • suitable for dry / damp / wet locations
  • 5 years warranty
  • for professional use only
  • This device must be installed by a qualified person.

Specifications

  • output:
    • DC voltage: 24 V
    • constant current region (Note.4): 12 V to 24 V
    • rated current: 25 A
    • rated power: 600 W
    • ripple & noise (max.) (Note.2): 150 mVp-p
    • voltage adj. range (Note.6): 20.4 to 25.2 V
    • current adj. range:
      • can be adjusted by internal potentiometer A type only
      • 12.5 to 25 A
    • voltage tolerance (Note.3): ± 1.0 %
    • line regulation: ± 0.5 %
    • load regulation (Note.8): ± 0.5 %
    • setup, rise time (Note.9): 500 ms, 80 ms at full load 230 VAC / 115 VAC
    • hold-up time (typ.): 15 ms at full load 230 VAC / 115 VAC
  • input:
    • voltage range: 90-305 VAC 127-431 VDC
    • frequency range: 47 to 63 Hz
    • power factor: PF ≥ 0.98 / 115 VAC , PF ≥ 0.95 / 230 VAC, PF ≥ 0.93 / 277 VAC at full load
    • total harmonic distortion: THD <20% when output loading ≥50% at 115VAC/230VAC input and output loading ≥75% at 277VAC input
    • efficiency (typ.) (230 VAC): 95 %
    • efficiency (typ.) (277 VAC): 95 %
    • AC current: 7 A / 115 VAC 3.3 A / 230 VAC 2.9 A / 277VAC
    • inrush current (typ.): cold start 70 A / 230 VAC
    • leakage current: < 0.75 mA / 277 VAC
  • protection:
    • overcurrent (Note.4):
      • 95 to 108 %
      • protection type: constant current limiting, recovers automatically after fault condition is removed
    • short-circuit: constant current limiting, recovers automatically after fault condition is removed
    • overvoltage:
      • 26 V to 30 V
      • protection type: shut down o/p voltage, re-power on to recover
    • overtemperature:
      • protection type: shut down o/p voltage, re-power on to recover
  • function:
    • remote on/off control:
      • power on: "Hi" > 2 - 5 V or (open circuit)
      • power off: "Low" < 0 - 0.5 V or (short circuit)
    • 5V standby: 5V SB : 5V@0.5A; tolerance +/-5%, ripple : 100mVp-p (max.)
  • environment:
    • working temp.: -40 °C to +70 °C (refer to "derating curve")
    • working humidity: 20 to 95 % RH non-condensing
    • storage temp., humidity: -40 °C to +85 °C, 10 to 95 % RH
    • temp. coefficient: ± 0.03 % / °C (0 °C to 60 °C)
    • vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
  • safety & EMC:
    • safety standards (Note.7): UL8750, CSA C22.2 No. 250-13-12, EN61347-1, EN61347-2-13 independent; IP65 approved
    • withstand voltage: I/P-O/P: 3.75K VAC I/P-FG: 2K VAC O/P-FG: 0.5K VAC
    • isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M ohms / 500 VDC / 25 °C / 70 % RH
    • EMC emission: in compliance with EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>50% load), EN6100-3-3
    • EMC immunity: in compliance with EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
  • others:
    • MTBF: 76.9K hrs min. MIL-HDBK-217F (25 °C)
    • dimensions: 280 x 144 x 48.5 mm

All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.

REACH communicating information according to article 33
WEEE

USA - English (UK)