DIGITAL MULTIMETER - CAT III 600V / CAT IV 300V - 15A - 6000 COUNTS - TRUE RMS

DVM898
Options (1)
Support
Downloads (2)
Warranty
Support
Compare

Features

  • CAT III 600V / CAT IV 300V
  • AC TRUE RMS
  • auto and manual range function
  • automatic polarity indication
  • automatic zero adjustment
  • voltage measurements: 600 VAC and 600 VDC max.
  • current measurements: DC 15 A max. and AC 15 A max.
  • resistance measurements: 60 MOhm max.
  • capacitance measurements: 99.99 mF max.
  • frequency measurements: 9.999 MHz max.
  • temperature measurements: -20°C to 1000°C (-4°F to 1832 °F)
  • with separate test leads (incl.): TLM72: PVC TEST LEAD SET - CAT IV 600 V - 15 A - 18 AWG - LENGTH 75 cm
  • pollution degree 2
  • Important safety information

Specifications

  • DC voltage: 0-60 mV / 600 mV / 6 V / 60 V / 600 V
    • basic accuracy: ± (0.8% rdg + 2 digits) , ± (0.5% rdg + 2 digits) for 600mV to 600 V range, ± (0.8% rdg + 2 digits) for 600V
    • input impedance: > 10 MOhm
    • overload protection: 600 V DC or AC rms
  • AC voltage: 0-60 mV / 600 mV / 6 V / 60 V / 600V
    • basic accuracy: ± (1.2% rdg + 3 digits) for 0 to 600 mV range , ± (0.8% rdg + 3 digits) for 6V to 600 V range, ± (1.2% rdg + 3 digits) for 600V
    • input impedance: > 10 MOhm
    • frequency range: 40 Hz - 1 kHz
    • overload protection: 600V DC or AC rms
    • AC true RMS
  • DC current: 0-600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 15 A
    • basic accuracy: ± (1.2% rdg + 2 digits) for 0 to 600 mA range, ± (2.0% rdg + 3 digits) for 6 A to 15 A range
    • overload protection: 0.8 A / 600 V fuse in µA and mA range; 15 A / 1000 V fuse in 15 A range
  • AC current: 0-600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 15 A
    • basic accuracy: ± (1.5% rdg + 3 digits) for 0 to 600 mA range, ± (2.5% rdg + 5 digits) for 6 A to 15 A range
    • frequency range: 40 Hz - 1 kHz
    • overload protection: 0.8 A / 600 V fuse in µA and mA range; 15 A / 1000 V fuse in 15 A range
  • resistance: 0-600 Ohm / 6 kOhm / 60 kOhm / 600 kOhm / 6 MOhm / 60 MOhm
    • basic accuracy: ± ( 1.0% rdg +3 digits); ± (1.0% rdg + 2 digits) for 6 kOhm to 6 MOhm range, ± (1.5% rdg + 3 digits) for 60 MOhm range
    • overload protection: 600 V DC or AC rms
    • open circuit voltage: approx. 0.5 V
  • capacitance: 0-9.999 nF / 99.99 nF / 999.9 nF / 9.999 µF / 99.99 µF / 999.9 µF / 9.999 mF / 99.99 mF
    • basic accuracy: ± (3.0% rdg + 10 digits); ± (2.5% rdg + 5 digits) for 99.99 nF to 9.999 µF range; ± (5.0% rdg + 10 digits) for 99.99 µF; ± (10.0% rdg + 20 digits) for 999.9 µF to 99.99 mF range
    • overload protection: 600 V DC or AC rms
  • frequency: 0-9.999 Hz / 99.99 Hz / 999.9 Hz / 9.999 kHz / 99.99 kHz / 999.9 kHz / 9.999 MHz
    • basic accuracy: ± ( 0.1% rdg + 5 digits)
    • sensitivity: sine wave 0.6 V rms (9.999 MHz = 1.5 V rms)
    • overload protection: 600 V DC or AC rms
  • temperature :
    • °C: -20 °C to 1000 °C
      • basic accuracy : ± (3 °C + 1 digit) for -20 0C to 150 °C range; ± (3% rdg + 2 digits) for 151 °C to 1000 °C range
    • °F : -4 °F to 1832 °F
      • basic accuracy: ± (5 °F + 2 digits) for -4 °F to 302 °F range; ± (3% rdg + 3 digits) for 303 °F to 1832 °F range
  • duty cycle: 0.1% - 99.9%
    • basic accuracy: ± (2.0% rdg + 2 digits)
    • sensitivity: sine wave 0.6 V rms
    • overload protection: 600 V DC or AC rms
  • audible continuity measurement: built-in buzzer sounds if resistance is less than 50 Ohm
    • test voltage: approx. 1.0 V
  • diode measurement: test forward voltage of diode
    • test voltage: approx. 3.2 V
  • overrange: yes
  • continuity buzzer: yes
  • diode test: yes
  • low-battery indication: yes
  • LCD display:
    • size: 60 x 28 mm
    • digits: max. 6000
  • ranging mode: auto and manual
  • data hold: yes
  • backlight: yes
  • auto power-off: yes
  • dimensions: 177 x 92 x 40 mm
  • weight (with battery): 320 g
  • power supply: 1 x 9 V 6F22C battery (incl.)
  • operating environment:
    • temperature: 0 °C to 40 °C (32 °F to 104 °F)
    • humidity: < 80% RH
  • storage environment:
    • temperature: -20 °C to 60 °C (-4 °F to 140 °F)
    • humidity: < 90% RH
  • fuse:
    • F0.5 A / 600 V 5 x 20 mm
    • F15A / 1000 V 5 x 20 mm
  • test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm

Options


TLM72

PVC TEST LEAD SET - CAT IV 600 V - 15...

Compare

Customers who viewed this product also viewed


DVM9915

DIGITAL AUTORANGE MULTIMETER - CAT...

Compare

DVM892N

DIGITAL MULTIMETER - 24 RANGES / CAT...

Compare

DVM856

DIGITAL MULTIMETER - CAT III 300 V /...

Compare

All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.

REACH communicating information according to article 33
WEEE

USA - English (UK)

Change