USA - English (UK)
Change

LCR AND IMPEDANCE METER

LCR45
Support
User manual
Warranty
Support
Compare

Features

  • supplied with removable, gold-plated hook probes
  • fluid measurements with hold function
  • automatic or manual component type
  • automatic or manual test frequency, DC, 1 kHz,15 kHz or 200 kHz
  • enhanced measurement resolution: 0.2 µH, 0.2 pF and 0.2 Ohm
  • easy menu system for user settings
  • enhanced compensation for component parasitics and losses (such as core losses, etc.)
  • automatic or manual power-off

Specifications

  • resistance:
    • range: 0 Ohm to 2 MOhm
    • resolution: 0.1 Ohm
    • accuracy: ± 1.0 % ± 0.6 Ohm
  • capacitance:
    • range: 0.5 pF to 10000 µF
    • resolution: 0.2 pF
    • accuracy: ± 1.5 % ± 0.6 pF
  • inductance:
    • range: 1 µH to 10 H
    • resolution: 0.2 µH
    • accuracy: ± 1.5 % ± 0.6 µH
  • passive component impedance:
    • Re & Im: ± 1.5 % ± 10 LSD
    • magnitude: ± 1.5 % ± 10 LSD
    • phase: ± 5 %
  • measurement sample rate: 0.5 Hz to 2 Hz
  • peak test voltage (across O/C): -1.05 V to 1.05 V
  • peak test current: -3.25 mA to 3.25 mA
  • test frequency accuracy:
    • 1 kHz: ± 0.5 %
    • 14.9254 kHz: ± 0.5 %
    • 200 kHz: ± 0.5 %
  • sine purity: +60 dB 3rd harmonic
  • operating temperature range: 10° C to 40° C / 50° F to 104° F
  • battery operating voltage: 8.5 V to 13 V

Customers who viewed this product also viewed


LCR40

AUTOMATIC PASSIVE COMPONENT ANALYZER

Compare

ESR70

Capacitance and ESR (Equivalent...

Compare

DCA75

ADVANCED SEMICONDUCTOR ANALYZER with...

Compare

All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.

REACH communicating information according to article 33
WEEE

USA - English (UK)

Change