- CAT. III - 1000 V, CAT. IV - 600 V
- measure: sound-level, light, humidity, temperature, DC & AC voltage, DC & AC current, frequency, capacitance, resistance, diode & continuity test, live wire test...
- low-battery indication
- autoranging (except ranges VAC 400 mV, IAC 10 A and IDC 10 A)
- built-in non-contact AC voltage detector (50-1000 VAC)
- voltage measurements: AC and DC 600 V max.
- current measurements: AC and DC max. 10 A
- capacitance : overload protection - 600 V AC or DC
- frequency sensitivity: < 1 MHz: >0.5 V rms / > 1 MHz: > 3 V rms
- resistance measurements: 40 Mohm max.
- sound level measurements: 35-100 dB
- resolution: 0.1 dB
- typ. instrument frequency: 30 Hz - 10 kHz
- frequency weighting: C
- accuracy: ± 5 dB at 94 dB sound level (1 kHz sine wave)
- microphone: electric condenser
- light measurements: up to 40 000 lux
- accuracy: ± 5% of rdg + 10 digits
- temperature characteristics: ± 0.1 % / °C
- photodiode: 1 silicon photodiode with filter
- humidity measurements: 33% - 99% rh
- resolution: 1% rh
- accuracy: ± 3% Rrh
- internal temperature measurements: 0°C to +50°C
- resolution: 0.1 °C
- accuracy: 3% of rdg ± 5 digits
- K-type thermocouple measuring range: -20 °C ~ +1300 °C
- resolution: 1 °C
- accuracy: 3% of rdg ± 5 digits
- Important safety information
Specifications
- DC voltage: 400 mV / 4 V / 40 V / 400 V / 600 V
- basic accuracy: ± 1.0% of rdg ± 4 digits for 0.4V~40V range / ± 1.5% of rdg ± 4 digits for 400V~600V range
- input impedance: 10Mohm
- maximum input: 600V
- AC voltage: 400 mV / 4 V / 400 V / 600 V
- basic accuracy: ± 1.5% of rdg ± 15 digits for 400mV range / ± 1.0% of rdg ± 4 digits for 4V~40V range / ± 1.5% of rdg ± 4 digits for 400V~600V range
- input impedance: 10 Mohm
- frequency range: 50 to 400Hz
- maximum input: 600Vac
- DC current: 400 µ / 4 m / 400 m / 10 A
- basic accuracy: ± 1.0% of rdg ± 2 digits for 400µA~4mA range/ ± 1.2% of rdg ± 2 digits for 400mA range / ± 2.0% of rdg ± 5 digits for 10A range
- overload protection: 500 mA / 600 V fuse & 10 A / 600 V fuse
- AC current: 400 µ / 4 m / 400 m / 10 A
- basic accuracy: ± 1.2% of rdg ± 2 digits for 400µA~4mA range/ ± 1.5% of rdg ± 2 digits for 400mA range / ± 2.0% of rdg ± 5 digits for 10A range
- overload protection: 500 mA / 600 V fuse & 10 A / 600 V fuse
- resistance: 400 / 4 k / 40 k / 400 k / 4 M / 40 M
- basic accuracy: ± 1.5% of rdg ± 4 digits for 400 ohms range / ± 1.5~2.0% of rdg ± 2 digits for 4k~40M range
- overload protection: 15 seconds max. 250 V on all ranges
- capacitance: 50.00 nF / 500.0 nF / 5.000 uF / 50.00 uF / 100.0 uF
- accuracy: ± 3.0 - 5.0 % of rdg ± 5-7 digits
- inductance: -
- frequency: 5 Hz / 50 Hz / 500 Hz / 5 kHz / 50 kHz / 500 kHz / 10 MHz
- basic accuracy: ± 1.2 % of rdg ± 3 digits
- overload protection: 250 V AC or DC
- temperature: -20 °C to +1300 °C
- basic accuracy: 3% of rdg ± 5 digits
- overrange: yes "OL"
- continuity buzzer: yes
- transistor test: no
- diode test: yes
- low-battery indication: yes
- maximum display: 3999
- LCD display:
- dimensions: 45 x 18 mm
- digits: 3 4/5
- ranging mode: autoranging
- data hold: yes
- backlight: yes
- dimensions: 170 x 78 x 48 mm
- weight (with battery): approx. 330 g
- power supply: 1 x 9 V battery 6F22 (incl.)
- packing: box
- accessories: manual / test leads / battery / K-type thermocouple
- auto power-off: yes
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.
REACH communicating information according to article 33
|
WEEE
|