Discontinued
Product description
- 6 000 counts LCD display with automatic polarity indication and settings information
- memory function for MIN/MAX values
- automatic or manual range selection
- data hold function
- continuity and diode test
- optical standard RS232C/USB interface for PC connection
- white backlight
- relative measurement mode for all ranges except frequency
- comes with WindowsXP software, optical USB cable, thermocouple, battery, IEC1010 measuring cables and user manual
- Important safety information
Specifications- DC voltage: 0,6V / 6 / 60 / 600 / 1000V
- basic accuracy: ±( 0,5% of reading + 8 digits) for 0.6V range , ±(0.8%+5digits) for 6/60/600V range , ±(1%+10digits) for 1000V range
- input impedance: > 10Mohm
- maximum input: 1000V
- AC voltage: 0,6V / 6 / 60 / 600 / 700V
- basic accuracy: ±( 3% of reading + 3 digits) for 0.6V range , ±(1%+3digits) for 6/60/600V range , ±(1,5%+3digits) for 700V range
- input impedance: > 10Mohm
- frequency range: 40-400Hz
- maximum input: 700V
- DC current: 600uA / 6m / 60m / 600m / 6A / 10A
- basic accuracy: ±( 1,5% of reading + 3 digits) for 600u / 6mA range , ±(1,8%+5digits) for 60/600mA range , ±(2%+5digits) for 6/10A range
- overload protection: 10A/600V-fuse for 10A-range , 750mA/600V fuse for other ranges
- AC current: 600uA / 6m / 60m / 600m / 6A / 10A
- basic accuracy: ±( 1,8% of reading + 5 digits) for 600u / 6mA range , ±(2%+8digits) for 60/600mA range , ±(3%+8digits) for 6/10A range
- overload protection: 10A/600V-fuse for 10A-range , 750mA/600V fuse for other ranges
- resistance: 600 / 6k / 60k / 600k / 6M / 60M
- basic accuracy: ±( 0,5% of reading + 3 digits) for 600 Ohm range , ±(0,5%+2digits) for 6K...6M range , ±(1,5%+3digits) for 60Mohm range
- overload protection: 250Vdc or 250Vrms
- capacitance: 60nF/ 600nF / 6uF / 60uF / 300uF
- accuracy: ±( 3% of reading + 20 digits) for 60 nF range , ±(3%+10digits) for 600nF...60uF range , ±(5%+10digits) for 300 uF range
- inductance: -
- frequency: 99.99Hz / 999.9Hz / 9.999kHz / 99.99 kHz / 999.9 kHz
- basic accuracy: ±( 0,1% of reading + 3 digits)
- overload protection: 250V dc or 250V ac rms
- temperature: -55°C to 1000°C
- basic accuracy: -55°C to 0°C : ±( 5% of reading + 4 digits) . 0 to 400°C : ±(2%+3digits). 400 to 1000°C : ±(2% of reading)
- overrange: yes "OL"
- continuity buzzer: yes
- transistor test: no
- diode test: yes
- low-battery indication: yes
- maximum display: 3 5/6
- LCD display size: -
- ranging mode: auto / manual
- data hold: yes
- backlight: yes
- dimensions: 85 x 180 x 45mm
- weight (with battery): ±300g
- power supply: 9V battery (incl.)
- packing: -
- accessories: user manual / test leads / battery / optical USB cable / PC-link software / K-type thermocouple
- auto power-off: selectable
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only. REACH communicating information according to article 33 |WEEE |