Product description
- 6 000 counts LCD display with automatic polarity indication and settings information
- memory function for MIN/MAX values
- automatic or manual range selection
- data hold function
- continuity and diode test
- white backlight
- relative measurement mode for all ranges except frequency
- IEC 61010-1:2001: CAT III 1000V / CAT IV 600V
- spare fuses: DVM4X00/FUSES (5x 630mA + 5x 10A/1000V)
- Important safety information
Specifications
- DC voltage: 0.6V / 6 / 60 / 600 / 1000V
- basic accuracy: ±(0.5% of rdg + 5 digits) for 0.6V range, ±(0.8% of rdg +5 digits) for 6 - 600V range, ±(1.0% of rdg+2 digits) for 1000V range
- input impedance: > 10Mohm
- maximum input: 1000V
- AC voltage: 0.6V / 6 / 60 / 600 / 1000V
- basic accuracy: ±(1.0% of rdg + 5 digits) for 0.6 - 600V range, ±(1.5% of rdg + 5 digits) for 1000V range
- input impedance: > 10Mohm
- frequency range: 40-400Hz
- maximum input: 1000V
- DC current: 600µA / 6m / 60m / 600m / 6A / 10A
- basic accuracy: ±(1.5% of rdg + 3 digits) for 0.6-600mA range, ±(1.5% of rdg + 5 digits) for 6-10A range
- overload protection: F10A/1000V-fuse for 10A-range , F0.63A/1000V fuse for other ranges
- AC current: 600µA / 6m / 60m / 600m / 6A / 10A
- basic accuracy: ±(1.8% of rdg + 5 digits) for 0.6-600mA range, ±(3.0% of rdg + 8 digits) for 6-10A range
- overload protection: F10A/1000V-fuse for 10A-range , F0.63A/1000V fuse for other ranges
- resistance: 600 / 6k / 60k / 600k / 6M / 60M
- basic accuracy: ±(0.5% of rdg + 3 digits) for 600 Ohm range, ±(0.5% of rdg + 2 digits) for 6K-6M range, ±(1.5% of rdg + 5 digits) for 60Mohm range
- overload protection: -
- capacitance: 60nF/ 600nF / 6µF / 60µF / 300µF
- accuracy: <10nF: ±(5.0% of (rdg - 50 digits) + 20 digits) / >10nF: ±(3.0% of rdg + 10 digits) for 60nF range, ±(5% of rdg + 10 digits) for all other ranges
- inductance: -
- frequency: 99.99Hz / 999.9Hz / 9.999kHz / 99.99 kHz / 999.9 kHz
- basic accuracy: logic: ±( 0.1% of rdg + 3 digits) / linear: ±( 0.05% of rdg + 8 digits) for 99.99Hz/999.9Hz/9.999KHz range
- overload protection: -
- temperature: -55°C to 1000°C
- basic accuracy: -55°C to 0°C: ±(5.0% of rdg + 4 °C), 1 to 400°C: ±(2.0% of rdg + 3°C), 401 to 1000°C: ±(2.0% of rdg)
- overrange: yes "OL"
- continuity buzzer: yes
- transistor test: no
- diode test: yes
- low-battery indication: yes
- maximum display: 3 5/6
- LCD display size: 30 x 60mm
- ranging mode: auto / manual
- data hold: yes
- backlight: yes
- dimensions: 190 x 90 x 40mm
- weight (with battery): ±500g
- power supply: 9V NEDA 1604 6F22 006P battery (incl.)
- packing: -
- accessories: user manual / test leads / battery / K-type thermocouple + socket
- auto power-off: yes
All registered trademarks and trade names are properties of their respective owners and are used only for the clarification of the compatibility of our products with the products of the different manufacturers.
Due to constant product improvements the actual product appearance might differ from the shown images. Product images are for illustrative purposes only.
REACH communicating information according to article 33
|
WEEE
|